TensorPhysics stress-tests your robot against the modelling errors you haven't measured yet, shows which actuators still hold, and tells your team what to bench-test first, before a prototype burns out.
- engine
- MuJoCo 3.10
- errors searched
- 8 per joint
- tests
- pre-registered
- actuators checked from public datasheets, every row sourced
- 48
- modelling errors searched per joint, alone and together
- 8
- for a full 7-joint arm study on a desktop CPU: 291 MuJoCo simulations
- < 4 min
- Panda joints where the lightest paper fit fails once errors stack
- 7 / 7
Most actuator choices are made on numbers that were never measured on the robot.
Datasheets give you the clean model. Friction, damping, armature and heat are often guessed. Our checks show how far one guess can move the answer.
- Panda joints where the lightest paper fit fails once errors stack.
- 7 of 7
- Go2 thigh actuator, damping 0 vs 2. No public measured value exists.
- 0.36 kg → 2.6 kg
- Torque difference between our inverse dynamics and Pinocchio RNEA on Go2, Solo-12 and ANYmal C.
- 0.000%
Independent work reports that actuator characteristics have a considerable influence on sim-to-real transfer for legged robots. arXiv 2204.03897
Send us your robot file. We'll tell you which numbers to measure before you buy actuators.
Test your URDF / MJCFAll results are from simulation on public robot models. They don't come from hardware tests. Bench data is next.
The lightest actuator that fits on paper melts once the model is wrong.
Real result from our Franka Panda study, shoulder joint J2. Stack every modelling error toward the top of its plausible range and watch which actuator still holds.
- mass
- 2.6 kg
- margin
- 8% over
- fails at
- 44%
ActuatorFit v1 · legged · real study
One unmeasured number moves the Go2 thigh actuator from 0.36 kg to 2.6 kg.
Unitree Go2, three planned tasks, 12 joints, every modelling error stacked. The only difference between the two runs is joint damping: Unitree's own robot file has none, the MuJoCo Menagerie model has 2 N·m·s/rad. Neither is a measurement.
- 12 actuators
- 5.84 kg
- thigh pick
- 0.36 kg
- worst joint u
- 0.96
Thigh: RMD-X4-P36-36. The lightest paper fit there, RobStride RS00 (0.31 kg), reaches u = 1.37 with every error stacked; it fails first on thermal. Across the robot, thermal is what breaks the lightest fits most often in this run.
Joint damping. It moves the total actuator mass from 5.84 kg to 17.42 kg on a 15 kg robot.
Find the seed that makes your physics explode, then prove the fix holds.
Fast bodies tunnel through thin floors. Stiff contacts gain energy from nothing. PhysicsFuzz hunts for those seeds automatically and replays them in CI.
- sim time
- 0.00 s
- stack energy
- 0.0 J
- failures
- 0
Overlay the simulation on the bench run. See exactly where reality leaves the model.
Cyan wireframe is what the model predicts; the solid arm is the measured run. Inject a fault, scrub the timeline, and watch the gap open. Our v0 test missed some friction gaps, so we say so here.
- gap now
- 0.0 mm
- worst gap
- 36.1 mm
- time over
- 48%
Friction gaps are where GapCheck v0 failed: 178 of 1,200 runs gave false assurance, and every one of them was a friction case. v1 adds a per-parameter detectability table.
Dial in how wrong the model is. See what breaks, and what to measure first.
Pick a joint and an actuator, then push the modelling errors. The callout tells you which bench test buys back the most margin.
Run the duty cycle on the bench and log winding temperature.
Thermal rating adds +0.20 to u here, more than any other error.
Under the hood.
One pipeline behind every product. Select a stage to trace its data path and read its log from the Panda run.
- errors
- 8
- sweep
- 9 levels to 5×
- adversary
- 50 evals
- worst u (pick)
- 0.93
- sweep5 physical errors × 9 levels × 3 tasks = 135 runs
- sweep3 datasheet errors, analytic, every actuator
- cornerall 8 at top of range → lightest paper fit fails 7/7 joints✗
- cornerrecommended set: worst u 0.933✓
- ars50 evals → worst 0.933, nothing worse than the corner✓
- trackmax error at corner 0.0137 rad < 0.02✓
We publish our failures.
Every test has its pass and fail lines fixed before it runs. Every claim carries a label: VERIFIED, REPORTED or INFERENCE. If it failed, it says failed.
Size your next robot against the errors you haven't measured yet.
ActuatorFit beta: bring your own MJCF or URDF, or start from a reference robot.