Give ActuatorFit your robot and the tasks it must do. It finds the actuators that fit every joint, then measures how far friction, inertia, payload, voltage and heat can drift before each one stops being enough.
- 01UploadMJCF or URDF, or start from a reference robot.
- 02Define tasksWaypoints, payloads, hold times. The robot tracks them in MuJoCo.
- 03Get a reportFits per joint, Gap Margin, and what to bench-test first.
The lightest fit failed on all 7 joints.
On every joint, the lightest actuator that fits on paper went over its limit once all eight modelling errors sat at the top of their plausible range together. Open a joint to see why.
2.6 kg and u 0.79 on paper, but over its limit once every error sits at the top of its range.
Measure first: Run the duty cycle on the bench and log winding temperature.
Demand: 72.8 Nm peak · 67.0 Nm RMS · 0.94 rad/s
Adversarial check on the recommended set: worst u 0.93 over 50 evaluations of all 8 errors together. PASS. Torque checks within 5%: PASS. Full study: 115 s, 291 simulations on a 2-vCPU machine. Tasks: Pick-and-place, 3 kg, 3 cycles · Fast reach, 1 kg · Extended hold, 3 kg, 5 s.
ActuatorFit v1 · legged · real study
One unmeasured number moves the Go2 thigh actuator from 0.36 kg to 2.6 kg.
Unitree Go2, three planned tasks, 12 joints, every modelling error stacked. The only difference between the two runs is joint damping: Unitree's own robot file has none, the MuJoCo Menagerie model has 2 N·m·s/rad. Neither is a measurement.
- 12 actuators
- 5.84 kg
- thigh pick
- 0.36 kg
- worst joint u
- 0.96
Thigh: RMD-X4-P36-36. The lightest paper fit there, RobStride RS00 (0.31 kg), reaches u = 1.37 with every error stacked; it fails first on thermal. Across the robot, thermal is what breaks the lightest fits most often in this run.
Joint damping. It moves the total actuator mass from 5.84 kg to 17.42 kg on a 15 kg robot.
- 01Runs each task in MuJoCo and logs torque, speed and power on every joint.
- 02Checks every actuator in a table of 48 built from public datasheets, each row linked to its source.
- 03Lists the fits per joint, lightest first, and flags joints where nothing fits.
- 04Sweeps 8 modelling errors one at a time, then all together, and runs an adversarial search for anything worse.
- 05Recommends the lightest actuator that still fits with every error at the top of its plausible range.
- Actuator self-weight is not fed back into the links yet.
- Torque-speed is a straight line plus the rated point; no thermal time model (RMS only).
- No gearbox backlash or compliance.
- Datasheet values are vendor claims; plausible error ranges are assumptions until GapCheck measures them.
- Arms and quadrupeds today; quadruped torques come from planned motions on a hard floor. Humanoids are next.
Run your own robot through it.
We are looking for engineers sizing joints on humanoids, legged robots and arms. You get a full study on your model; we get your honest feedback.
- — Your model stays private to your account
- — Every report ships its assumptions and raw results
- — Free during the beta